First fatigue cracking was found in the girder web in Nov. 1973 after 9 years of service. The following fatigue cracking was found in the butt connection groove weld of the longitudinal stiffeners which are fillet weld connected to the girder webs. At the time of discovery, the first crack had propagated in the depth of the web and had gone into the bottom flange. Therefore, repair was required immediately.
This bridge is continuous for four spans and is non-composite Gerber bridge, which consist of suspended span on center, except for span 1. The complete and elevation views are shown in figure 1. The structure is composed of nine main girders on half side lane. Transverse cross bracings of X-type exist between the main girders.
Longitudinal stiffeners are fillet welded to the girder web (Fig.2).
File not found: "quinni15.jpg" at page "Yellow Mill Pond Br. (Cover plate ends, stress concentration)"[ź]
File not found: "quinni16.jpg" at page "Yellow Mill Pond Br. (Cover plate ends, stress concentration)"[ź]
Fig.1 Complete and elevation views.
File not found: "quinni17.gif" at page "Yellow Mill Pond Br. (Cover plate ends, stress concentration)"[ź]
Fig.2 Typical cross section.
Fluctuating loads due to vehicles live load.
Fatigue cracking which was found in the girder web originated from the butt connection groove weld of the longitudinal stiffeners (Fig.3,4). The fracture in the girder web resulted from a fatigue crack (Fig.3).
File not found: "quinni18.jpg" at page "Yellow Mill Pond Br. (Cover plate ends, stress concentration)"[ź]
Fig.3 Crack originated from the butt connection groove weld of the longitudinal stiffeners.File not found: "quinni19.jpg" at page "Yellow Mill Pond Br. (Cover plate ends, stress concentration)"[ź]
Fig.4 Crack propagated in the girder web.
From thorough investigation of fracture, it turned that non-deposited part of butt weld of horizontal stiffener caused and crack were originated at intersection of web plate and stiffener. It is probable that cracks in non-deposited part propagated during transportation and erection.
Web plate was brittle-fractured from the first fatigue crack. The crack became unstable and propagated rapidly and stopped around the center of flange or web plate. It is found there are some stages in which cracks propagates.
The portion crack appeared was cut off and splice plate was attached by bolts(Fig.5). For cracks which did not propagate so much, drill holes were opened on web plate and cracks were separated from the girder(Fig.6).